{"product_id":"eastman-em20060tt-200ah-12v-tall-tubular-inverter-battery","title":"Eastman EM20060TT 200Ah 12V Tall Tubular Inverter Battery","description":"\u003cdiv class=\"qMYqUG_convSearchResultHighlightRoot\"\u003e\n\u003cdiv class=\"\"\u003e\n\u003csection class=\"text-token-text-primary w-full focus:outline-none has-data-writing-block:pointer-events-none [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto R6Vx5W_threadScrollVars scroll-mb-[calc(var(--scroll-root-safe-area-inset-bottom,0px)+var(--thread-response-height))] scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-8 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv dir=\"auto\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\" tabindex=\"0\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eEastman EM20060TT 200Ah Tall Tubular Battery\u003c\/strong\u003e is a heavy-duty inverter battery designed for homes, offices, schools, hospitals, businesses and other locations that require dependable backup power.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIts tall tubular construction is designed for repeated charging and discharging, making it suitable for inverter and compatible solar backup systems. The battery includes an \u003cstrong\u003eelectrolyte level indicator\u003c\/strong\u003e, helping users monitor water levels and perform maintenance when required.\u003c\/p\u003e\n\u003ch2\u003e🔋 Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e12V 200Ah battery capacity\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHeavy-duty tall tubular construction\u003c\/li\u003e\n\u003cli\u003eDesigned for inverter and compatible solar applications\u003c\/li\u003e\n\u003cli\u003eSuitable for approximately \u003cstrong\u003e700VA to 2000VA inverters\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible with sine-wave and square-wave inverters\u003c\/li\u003e\n\u003cli\u003eElectrolyte level indicators for easier maintenance\u003c\/li\u003e\n\u003cli\u003eLow water loss\u003c\/li\u003e\n\u003cli\u003eReduced fumes generation\u003c\/li\u003e\n\u003cli\u003eGood overcharge tolerance\u003c\/li\u003e\n\u003cli\u003eReliable performance during repeated power interruptions\u003c\/li\u003e\n\u003cli\u003eEasy recovery after extended idle periods\u003c\/li\u003e\n\u003cli\u003eUp to \u003cstrong\u003e5% additional capacity and backup\u003c\/strong\u003e relative to rated capacity\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78-month warranty: 39 months flat and 39 months pro-rata\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\u003c\/div\u003e\n\u003ch2\u003e✅ Tall Tubular Battery Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for frequent and extended power outages\u003c\/li\u003e\n\u003cli\u003eLonger service life than many conventional flat-plate batteries\u003c\/li\u003e\n\u003cli\u003eGood deep-cycle performance\u003c\/li\u003e\n\u003cli\u003eReliable operation under demanding backup conditions\u003c\/li\u003e\n\u003cli\u003eLower water loss\u003c\/li\u003e\n\u003cli\u003eEasier electrolyte monitoring\u003c\/li\u003e\n\u003cli\u003eGood resistance to repeated charging and discharging\u003c\/li\u003e\n\u003cli\u003eSuitable for residential and heavy-duty applications\u003c\/li\u003e\n\u003cli\u003eDesigned for efficient recovery after long idle periods\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e💧 Electrolyte Level Indicators\u003c\/h2\u003e\n\u003cp\u003eThe battery includes visible electrolyte level indicators to help users identify when distilled water may need to be added.\u003c\/p\u003e\n\u003cp\u003eUnlike sealed gel or lithium batteries, this is a \u003cstrong\u003eserviceable flooded lead-acid battery\u003c\/strong\u003e and may require periodic water-level checks. Only approved distilled or battery water should be used, following the manufacturer’s instructions.\u003c\/p\u003e\n\u003ch2\u003e🔗 Battery-Bank Configuration\u003c\/h2\u003e\n\u003cp\u003eCompatible Eastman batteries may be connected to create higher-voltage or higher-capacity battery banks.\u003c\/p\u003e\n\u003cp\u003eExamples include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 batteries in series:\u003c\/strong\u003e 24V 200Ah\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 batteries in series:\u003c\/strong\u003e 48V 200Ah\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 batteries in parallel:\u003c\/strong\u003e 12V 400Ah\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll batteries in a bank should preferably be of the same brand, model, capacity, age and condition. Installation should be completed by a qualified technician.\u003c\/p\u003e\n\u003ch2\u003e⚠️ Charging and Installation Notice\u003c\/h2\u003e\n\u003cp\u003eBefore installation, confirm that the inverter or solar charge controller supports:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e12V tubular lead-acid batteries\u003c\/li\u003e\n\u003cli\u003eThe correct charging voltage\u003c\/li\u003e\n\u003cli\u003eSuitable charging current\u003c\/li\u003e\n\u003cli\u003eAppropriate low-voltage cut-off settings\u003c\/li\u003e\n\u003cli\u003eCorrect cable sizes and protection devices\u003c\/li\u003e\n\u003cli\u003eThe required number of batteries for the inverter voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eInstall the battery upright in a dry, secure and well-ventilated location away from flames, sparks and direct heat.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-3 w-full empty:hidden\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Werlar Solar Equipment \u0026 Machinery","offers":[{"title":"Default Title","offer_id":52579950002308,"sku":null,"price":51000.0,"currency_code":"KES","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1018\/2872\/2820\/files\/81N-ckJ48GL._SL1500.jpg?v=1785513943","url":"https:\/\/werlar.com\/products\/eastman-em20060tt-200ah-12v-tall-tubular-inverter-battery","provider":"Werlar Solar Equipment \u0026 Machinery","version":"1.0","type":"link"}